FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 1 of 52
A/D Converter
FAD-40
Technical Manual
Flintec GmbH
Bemannsbruch 9
74909 Meckesheim
GERMANY
www.flintec.com
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - Technical Manual

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 1 of 52 A/D Converter FAD-4

Seite 2

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 10 of 52 4. INSTALLATION PRECAUTION: Please read this manual carefully before you install th

Seite 3 - RIGHTS AND LIABILITIES

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 11 of 52 poor ground can result in an unsafe and unstable operation. It is important that the

Seite 4 - 1. SAFETY INSTRUCTIONS

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 12 of 52 4.2.4. Communication Interface Please refer to the corresponding chapter: FAD-40 (

Seite 5 - EC-Declaration of Conformity

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 13 of 52 5. SETUP PRECAUTION: Please read this manual carefully before energizing the instru

Seite 6 - 3. INTRODUCTION

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 14 of 52 5.3. A/D Converter Setup and Calibration WARNING: Read this manual carefully befor

Seite 7 - Specifications

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 15 of 52 Motion Detection This parameter defines the motion detection window which determines

Seite 8

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 16 of 52 Checksum The checksum can be enabled or disabled within BSI data format. The checksu

Seite 9 - 3.4. Accessories

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 17 of 52 Select the scale operation mode and the polarity. Then click the “Write to A/D Conve

Seite 10 - 4. INSTALLATION

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 18 of 52 Span Adjustment If your scale has a span drift, you may perform a span adjustment on

Seite 11 - 4.2.2. Load Cell Connection

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 19 of 52 I/O1: Select function and polarity for I/O1 (output only) I/O2: Select function and

Seite 12 - 4.3. Commissioning

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 2 of 52 Table of Contents: 1. SAFETY INSTRUCTIONS ...

Seite 13 - 5. SETUP

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 20 of 52 5.6. Bus Interface Setup FAD-40 instruments have a bus interface and these paramete

Seite 14 - 5.3.1. Scale Parameters

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 21 of 52 5.9. BSI Data Structure (for FAD-40 and FAD-40MB only) Depending on their functiona

Seite 15

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 22 of 52 Commands and Responses A Read all weight data Command: [ADR][A] Response: [AD

Seite 16 - Figure 5.4 – Calibration

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 23 of 52 Q Load setpoints Command: [ADR][Q][SP NUMBER][SP TYPE][SIGN][SP VALUE] Response:

Seite 17 - Calibration by Test Weights

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 24 of 52 V Read digital outputs Command: [ADR][V] Response: [ADR][V][A][OUTPUTS] Exa

Seite 18 - 5.5. Setup of Digital I/O

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 25 of 52 5.10. Modbus Data Structure (for FAD-40MB and FAD-40EN only) Address R/W Word Comma

Seite 19

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 26 of 52 Address R/W Word Command Definition 40015 R/W 1 mV operation in Count Mode 0 5 mV 1

Seite 20 - 5.6. Bus Interface Setup

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 27 of 52 Address R/W Word Command Description 40021 R/W 2 Setpoint 1 Low for I/O1 40023 R/W 2

Seite 21 - Status Table:

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 28 of 52 5.11. Profibus and ProfiNet Data Structure (for FAD-40Px only) Hardware Configuratio

Seite 22 - Commands and Responses

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 29 of 52 FAD-40Px Output to PLC Input 3rd Dword Bit no. 3rd Dword Description D31…D21 Not in

Seite 23

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 3 of 52 10. FAD-40CO – WITH CANOPEN INTERFACE ...

Seite 24

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 30 of 52 PLC Output to FAD-40Px Input Dword D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20

Seite 25

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 31 of 52 PLC Output to FAD-40Px Input 3rd Dword Bit no. 3rd Dword descriptions D31…D19 Not i

Seite 26

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 32 of 52 5.12. CANopen Data Structure (for FAD-40CO only) Hardware Configuration Hint To inst

Seite 27 - EXPLANATION

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 33 of 52 FAD-40CO Output to PLC Input T_DW3 Bit no. TxPDO 3 (T_DW3) Description D31…D21 Not

Seite 28

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 34 of 52 PLC Output to FAD-40CO Input Dword D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D2

Seite 29

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 35 of 52 PLC Output to FAD-40CO Input R_DW3 Bit no. R_DW3 descriptions D31…D19 Not in use D1

Seite 30

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 36 of 52 6. FAD-40 / FAD-40MB – WITH RS-485 INTERFACE FAD-40 and FAD-40MB instruments are st

Seite 31

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 37 of 52 6.2. Electrical Connections RS-485 connection is shown in figure 6.2. Figure 6.2

Seite 32

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 38 of 52 7. FAD-40PB – WITH PROFIBUS INTERFACE FAD-40PB instruments are state-of-the-art str

Seite 33

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 39 of 52 ST Status LED State Indication Comment Off No power or not initialized No power or p

Seite 34 - I/O Configuration

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 4 of 52 1. SAFETY INSTRUCTIONS CAUTION READ this manual BEFORE operating or servicing thi

Seite 35

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 40 of 52 Load Cell Connection See chapter 4.2.2 Digital I/O Connection See chapter 4.2.3 Powe

Seite 36 - INTERFACE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 41 of 52 8. FAD-40PN – WITH PROFINET INTERFACE FAD-40PN instruments are state-of-the-art str

Seite 37 - 6.4. Setup and Calibration

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 42 of 52 MS Module Status LED LED State Description Comment Off No power or not initialized N

Seite 38 - – WITH PROFIBUS INTERFACE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 43 of 52 See chapter 4.4.2 Digital I/O Connection See chapter 4.2.3 Power Supply Connection S

Seite 39 - 7.2. Electrical Connections

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 44 of 52 9. FAD-40EN – WITH ETHERNET INTERFACE FAD-40EN instruments are state-of-the-art str

Seite 40 - 7.5. Profibus Setup

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 45 of 52 9.2. Electrical Connections Ethernet and RS-232C connections are shown in figure 9

Seite 41 - – WITH PROFINET INTERFACE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 46 of 52 Load Cell Connection See chapter 4.2.2 Digital I/O Connection See chapter 4.2.3 Powe

Seite 42

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 47 of 52 10. FAD-40CO – WITH CANOPEN INTERFACE FAD-40CO instruments are state-of-the-art stra

Seite 43 - 8.5. ProfiNet Setup

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 48 of 52 RUN LED State Indication Comment Off No power or not initialized No power or cable b

Seite 44 - – WITH ETHERNET INTERFACE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 49 of 52 CANopen Interface Use Interfacing with PC or PLC Data format CANopen Baud rate Autom

Seite 45 - Ethernet Interface

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 5 of 52 2. DECLARATION OF CONFORMITY EG-Konformitätserklärung EC-Declaration of Conform

Seite 46 - 9.5. Ethernet Setup

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 50 of 52 11. ERROR TABLE The FAD-40 A/D Converters have been designed as very reliable and v

Seite 47 - – WITH CANOPEN INTERFACE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 51 of 52 12. DIAGNOSTICS In this test menu serial interface tests (RC-232C and/or RS-485) and

Seite 48 - CANopenCANopen

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 52 of 52 13. FREQUENTLY ASKED QUESTIONS Question : My PC cannot communicate with the FAD-4

Seite 49 - 10.5. CANopen Setup

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 6 of 52 3. INTRODUCTION 3.1. Overview The type FAD-40 A/D Converter Series consists of powe

Seite 50 - 11. ERROR TABLE

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 7 of 52 3.2. Key features and Specifications Key Features FAD-40 FAD-40MB FAD-40PB FAD-40PN

Seite 51 - 12. DIAGNOSTICS

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 8 of 52 Communication and Setup: Serial interface RS232C with 9600 baud (8,N,1); for FAD-40

Seite 52 - WWW.FLINTEC.COM

FAD-40 Technical Manual, Rev. 1.06 December 2012 Page 9 of 52 Instrument with CANopen interface: Type FAD-40CO Communication: CANopen V.2.0 10 kbit