Manual MCS-64: Modbus on Ethernet
Page 11
2061 Int16 1 R/W Bit commands. Functions regardless of the setting of the LDM
selector register.
Bit 1: Reset Zero (RZ)
Bit 2: Set Zero (SZ)
Bit 3: Reset Tare (RT)
Bit 4: Set Tare (ST)
Bit 5 – 7: unused
Bit 8 –15: LDM#
Write a “1” to activate function, reads as “1” until command done
2062 Int16 1 R/W Trigger: Functions regardless of the setting of the LDM selector
register.
Write the LDM number to trig LDM;
Write the LDM number + 80h(128 dec) to cancel measurements
(LDM 88.183 only)
2063 Int16 1 R/W Parameter page select. Valid values= [0..4].
General parameter values
Calibration parameter values
Filling parameter values
Check weigher parameter values
Mass flow parameter values
2064 Int16 1 R/W TAC access, see calibration page.
2065 Int16 1 R/W START / ABORT filling process.
Writing a Non-zero value starts filling process.
Writing a zero ABORTS filling process.
2066 Int16 1 R/W EEPROM functions:
Bit 1: Save analogue parameters (AS)
Bit 2: Save calibration (CS); TAC protected
Bit 3: Save general setup parameters (WP)
Bit 4: Save dosing parameters (SD)
Bit 5: Save setpoint parameters (SS)
Bit 6 –14: unused
Bit 15: Factory default; TAC protected
2067 Int16 1 R/W Set-point select [0..3]
2068 Int32 2 R/W Set-point source
206A Int32 2 R/W Set-point hysteresis
206C Int32 2 R/W Set-point Value
206E Int16 1 R Read the dose info:
Bit value Meaning
$0001 Coarse valve open
$0002 Fine valve open
$0004 Dose program running
$0008 Not used
$0010 Not used
$0020 Not used
$0040 Tare out of range – no filling in this cycle
$0080 Zero out of range
$FF00 The High byte has the following interpretation:
00= Idle
01= Waiting for trigger(2
nd
trigger)
02= Bottle on, calculating tare
03= Pre-fill
04= Main Filling
05= Fine Filling
06= In-flight delay
07= Post fill calculations
08= Post Filling
Seitenansicht 10