DAD 141.1 Technical Manual Modbus Communication, Rev. 2.3 - Juni 2014 Page 10
This Index Reads/Modify the delay between falling/rising edge of the trigger pulse and start of the
measurement. The 32 bit integer data accessed by reading or writing 2 16-bit registers from index
2412.
see also command description: SD Start Delay
This Index reads the four most significant bytes of the MAC address.
The 32 bit integer data accessed by reading 2 16-bit registers from index 3006.
This Index reads the two least significant bytes of the MAC address.
The 32 bit integer data accessed by reading 2 16-bit registers from index 3008.
This Index reads/Modify the IP Address. A change will take effect after reset.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 300C.
see also command description: NA Network Address
This index reads the gross weight, the net weight and the qualifier.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 3300.
see also command description: GW Get data string “net, gross and status“
Combined
result, floating
point
This index reads the gross weight, the net weight and the qualifier.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 3500.
see also command description: GW Get data string “net, gross and status“