DAD 141.1 Technical Manual Modbus Communication, Rev. 2.3 - Juni 2014 Page 7
This Index defines the weight value for the high analog output.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2102.
see also command description: AH Analog High
This Index defines the weight value for the low analog output.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2104.
see also command description: AL Analog Low
This Index is used to select the filter setting.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2106.
The values of the low pass filters are 0 to 7.
see also command description: FL Filter Value
This Index Reads/Modify the status of the physical output signals.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 210A.
see also command description: IO Status of the logic Output
This Index reads the status of the physical input signals.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 210C.
see also command description: IN Read status of logic Input
This Index chooses the filter mode, permitted values are “0” for IIR and “1” for FIR.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2110.
see also command description: FM Filter Mode
This Index Reads/Modify the maximum number of counts allowed as no motion.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2112.
see also command description: NR No Motion Range
This Index Reads/Modify the minimum time the weight must stay within NR to be no motion.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2114.
see also command description: NT No MotionTime
This Index Reads/Modify the mask of the logic Outputs.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2116.
see also command description: OM Control of logic Outputs
This Index Reads the Tare value.
The 32 bit integer data accessed by reading 2 16-bit registers from index 2118.
see also command description: GT Get tare value
This Index chooses Average after the filter by 2 exp. UR samples.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2120.